Based on mass-loading effect on a microcantilever, there are two approaches for sensing the presence of molecules: dynamic and static methods. In this paper, we demonstrate that the two methods actually use the same form of relationships for their sensing purposes and, if the designed adhesion region of a cantilever is only partially occupied by molecules, then neither method can be applied to accurately determine the number of molecules adsorbed.

1.
Thundat
,
T.
,
Warmack
,
R. J.
,
Chen
,
G. Y.
, and
Allison
,
D. P.
, 1994, “
Thermal and Ambient-Induced Deflections of Scanning Force Microscope Cantilevers
,”
Appl. Phys. Lett.
0003-6951,
64
, pp.
2894
2896
.
2.
Thundat
,
T.
,
Sharp
,
S. L.
,
Fisher
,
W. G.
,
Warmack
,
R. J.
, and
Wachter
,
E. A.
, 1995, “
Micromechanial Radiation Dosimeter
,”
Appl. Phys. Lett.
0003-6951,
66
, pp.
1563
1565
.
3.
llic
,
B.
,
Czaplewski
,
D.
,
Craighead
,
H. G.
,
Neuzil
,
P.
,
Campagnolo
,
C.
, and
Batt
,
C.
, 2000, “
Mechanical Resonant Immunospecific Biological Detector
,”
Appl. Phys. Lett.
0003-6951,
77
, pp.
450
452
.
4.
llic
,
B.
,
Czaplewski
,
D.
,
Craighead
,
H. G.
,
Neuzil
,
P.
,
Campagnolo
,
C.
, and
Batt
,
C.
, 2001, “
Single Cell Detection With Micromechanical Oscillators
,”
J. Vac. Sci. Technol. B
0734-211X,
19
, pp.
2825
2828
.
5.
Thomson
,
W. T.
, 1988,
Theory of Vibration with Applications
, Third Edition,
Prentice-Hall
, Englewood Cliffs, NJ, pp.
156
158
and
299
304
.
6.
Weaver
,
W.
,
Timoshenko
,
S. P.
, and
Young
,
D. H.
, 1990,
Vibration Problems in Engineering
, Fifth Edition,
Wiley
, New York, p.
428
.
7.
Timoshenko
,
S. P.
, and
Gere
,
J. M.
, 1972,
Mechanics of Materials
,
Van Nostrand Reinhold
, New York.
8.
Davis
,
Z. J.
,
Abadal
,
G.
,
Kuhn
,
O.
,
Hansen
,
O.
,
Grey
,
F.
, and
Boisen
,
A.
, 2000, “
Fabriation and Characterization of Nanoresonating Devices for Mass Detection
,”
J. Vac. Sci. Technol. B
0734-211X,
18
, pp.
612
616
.
9.
Abadal
,
G.
,
Davis
,
Z. J.
,
Borrisé
,
X.
,
Hansen
,
O.
,
Boisen
,
A.
,
Barniol
,
N.
,
Pérez-Murano
,
F.
, and
Serra
,
F.
, 2003, “
Atomic Force Microscope Characterization of a Resonating Nanocantilever
,”
Ultramicroscopy
0304-3991,
97
, pp.
127
133
.
10.
Manual of the LEO Transmission Electron Microscopy
,
LEO Electron Microscopy Inc.
, Thornwood, NY.
11.
Berger
,
R.
,
Delamarche
,
E.
,
Lang
,
H. P.
,
Gerber
,
C.
,
Gimzewski
,
J. K.
,
Meyer
,
E.
, and
Güntherdot
,
H.-J.
, 1997, “
Surface Stress in the Self-Assembly of Alkanethiols on Gold
,”
Science
0036-8075,
276
, pp.
2021
2024
.
12.
Lang
,
H. P.
,
Berger
,
R.
,
Battiston
,
F.
,
Ramseyer
,
J.-P.
,
Meyer
,
E.
,
Andreoli
,
C.
,
Brugger
,
J.
,
Vettiger
,
P.
,
Despont
,
M.
,
Mezzacasa
,
T.
,
Scandella
,
L.
,
Güntherdot
,
H.-J.
,
Gerber
,
Ch.
, and
Gimzewski
,
J. K.
, 1998, “
A Chemical Sensor Based on a Micromechanical Cantilever Array for the Identification of Gases and Vapors
,”
Appl. Phys. A: Mater. Sci. Process.
0947-8396,
66
,
S61
S64
.
13.
Moulin
,
A. M.
,
O’Shea
,
S. J.
,
Badley
,
R. A.
,
Doyle
,
P.
, and
Welland
,
M. E.
, 1999, “
Measuring Surface-Induced Conformational Changes in Protein
,”
Langmuir
0743-7463,
15
, pp.
8776
8779
.
14.
Fritz
,
J.
,
Baller
,
M. K.
,
Lang
,
H. P.
,
Rothuizen
,
H.
,
Vettiger
,
P.
,
Meyer
,
E.
,
Güntherdot
,
H.-J.
,
Gerber
,
Ch.
, and
Gimzewski
,
J. K.
, 2000, “
Translating Biomolecular Recognition Into Nanomechanics
,”
Science
0036-8075,
288
, pp.
316
318
.
15.
Spiering
,
V. L.
,
Bouwstra
,
S.
, and
Spiering
,
R.
, 1993, “
On Chip Decoupling Zone for Package-Stress Reduction
,”
Sens. Actuators, A
0924-4247,
39
, pp.
149
156
.
16.
Hibbeler
,
R. C.
, 1994,
Mechanics of Materials
,
Prentice-Hall
, Englewood Cliffs, NJ, p.
134
.
You do not currently have access to this content.