Axial loading of the lower leg during impact events can cause significant fractures of the tibia. The magnitude of lower leg axial loading that occurs during short-duration high-impulse events, such as antivehicular landmine blasts, can lead to life-altering injuries. These events achieve higher forces over shorter durations than car crashes, the current standard used for protective measures. In order to determine appropriate injury limits for the lower limb, a testing apparatus has been designed that can simulate these types of events for testing of anthropomorphic test device (ATD) lower legs as well as cadaveric specimens. Moreover, the design allows for the velocity at which the specimen is struck to be varied independently of the force applied, thus allowing independent investigation into the effect of momentum or energy on fracture strength. Test specimens are supported on a low-friction bearing system, and receive the controlled impulse from a projectile of variable mass that is accelerated using pneumatics. The apparatus includes velocity sensors, a six-degree-of-freedom load cell, and an accelerometer to completely quantify the loading event. The apparatus’ performance was validated against an ATD lower leg. It was able to create impulse events with forces from 0.5 kN to 17.0 kN, and projectile speeds of 2.3–13.9 m/s. Various momenta could be achieved at a constant force level by varying the mass of the projectile, with a maximum difference of 65%, whereas kinetic energy was inherently linked to the impact force. This apparatus will be useful in future studies for determining the appropriateness of currently used injury limits for the lower limb to high-impulse events, as well as for quantifying the relationship between cadaveric fracture response and ATD measurements. This device can also be readily applied to other bones of the body, to create realistic fracture patterns for known injury mechanisms.
Skip Nav Destination
e-mail: cdunning@uwo.ca
Article navigation
January 2010
Technical Briefs
Development of an Apparatus to Produce Fractures From Short-Duration High-Impulse Loading With an Application in the Lower Leg
Cheryl E. Quenneville,
Cheryl E. Quenneville
Jack McBain Biomechanical Testing Laboratory, Thompson Engineering Building,
The University of Western Ontario
, London, ON, N6A 5B9, Canada; Department of Mechanical and Materials Engineering, The University of Western Ontario
, London, ON, N6A 5B9, Canada
Search for other works by this author on:
Gillian S. Fraser,
Gillian S. Fraser
Biomedical Engineering Graduate Program,
The University of Western Ontario
, London, ON, N6A 5B9, Canada; General Dynamics Land Systems Canada, Engineering Design and Development
, London, ON, N5V 2Z7, Canada
Search for other works by this author on:
Cynthia E. Dunning
Cynthia E. Dunning
Jack McBain Biomechanical Testing Laboratory, Thompson Engineering Building,
e-mail: cdunning@uwo.ca
The University of Western Ontario
, London, ON, N6A 5B9, Canada; Biomedical Engineering Graduate Program, The University of Western Ontario
, London, ON, N6A 5B9, Canada; Department of Mechanical and Materials Engineering, and Department of Surgery, The University of Western Ontario
, London, ON, N6A 5B9, Canada
Search for other works by this author on:
Cheryl E. Quenneville
Jack McBain Biomechanical Testing Laboratory, Thompson Engineering Building,
The University of Western Ontario
, London, ON, N6A 5B9, Canada; Department of Mechanical and Materials Engineering, The University of Western Ontario
, London, ON, N6A 5B9, Canada
Gillian S. Fraser
Biomedical Engineering Graduate Program,
The University of Western Ontario
, London, ON, N6A 5B9, Canada; General Dynamics Land Systems Canada, Engineering Design and Development
, London, ON, N5V 2Z7, Canada
Cynthia E. Dunning
Jack McBain Biomechanical Testing Laboratory, Thompson Engineering Building,
The University of Western Ontario
, London, ON, N6A 5B9, Canada; Biomedical Engineering Graduate Program, The University of Western Ontario
, London, ON, N6A 5B9, Canada; Department of Mechanical and Materials Engineering, and Department of Surgery, The University of Western Ontario
, London, ON, N6A 5B9, Canadae-mail: cdunning@uwo.ca
J Biomech Eng. Jan 2010, 132(1): 014502 (4 pages)
Published Online: December 8, 2009
Article history
Received:
December 19, 2008
Revised:
May 25, 2009
Posted:
September 1, 2009
Published:
December 8, 2009
Online:
December 8, 2009
Citation
Quenneville, C. E., Fraser, G. S., and Dunning, C. E. (December 8, 2009). "Development of an Apparatus to Produce Fractures From Short-Duration High-Impulse Loading With an Application in the Lower Leg." ASME. J Biomech Eng. January 2010; 132(1): 014502. https://doi.org/10.1115/1.4000084
Download citation file:
Get Email Alerts
How Irregular Geometry and Flow Waveform Affect Pulsating Arterial Mass Transfer
J Biomech Eng (December 2024)
Phenomenological Muscle Constitutive Model With Actin–Titin Binding for Simulating Active Stretching
J Biomech Eng (January 2025)
Image-Based Estimation of Left Ventricular Myocardial Stiffness
J Biomech Eng (January 2025)
Related Articles
Predicting Distal Radius Bone Strains and Injury in Response to Impacts Using Multi-Axial Accelerometers
J Biomech Eng (October,2012)
Ankle Rehabilitation via Compliant Mechanisms
J. Med. Devices (June,2010)
The Axial Injury Tolerance of the Human Foot/Ankle Complex and the Effect of Achilles Tension
J Biomech Eng (December,2002)
Ambulatory Device for Urinary Incontinence Detection in Female Athletes
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
In Situ Observations of the Failure Mechanisms of Hydrided Zircaloy-4
Zirconium in the Nuclear Industry: 20th International Symposium
The Design and Implement of Remote Inclinometer for Power Towers Based on MXA2500G/GSM
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Design of a Tri-Axial Accelerometer for Low Frequency Vibration
International Conference on Instrumentation, Measurement, Circuits and Systems (ICIMCS 2011)