It is well known that blood has non-Newtonian properties, but it is generally accepted that blood behaves as a Newtonian fluid at shear rates above 100 s−1. However, in transient conditions, there are times and locations where the shear rate is well below 100 s−1, and it is reasonable to infer that non-Newtonian effects could become important. In this study, purely viscous non-Newtonian (generalized Newtonian) properties of blood are incorporated into the simulation-based framework for cardiovascular surgery planning developed by Taylor et al. (1999, “Predictive Medicine: Computational Techniques in Therapeutic Decision Making,” Comput. Aided Surg., 4, pp. 231–247; 1998, “Finite Element Modeling of Blood Flow in Arteries,” Comput. Methods Appl. Mech. Eng., 158, pp. 155–196). Equations describing blood flow are solved in a patient-based abdominal aortic aneurysm model under steady and physiological flow conditions. Direct numerical simulation (DNS) is used, and the complex flow is found to be constantly transitioning between laminar and turbulent in both the spatial and temporal sense. It is found for the case simulated that using the non-Newtonian viscosity modifies the solution in subtle ways that yield a mesh-independent solution with fewer degrees of freedom than the Newtonian counterpart. It appears that in regions of separated flow, the lower shear rate produces higher viscosity with the non-Newtonian model, which reduces the associated resolution needs. When considering the real case of pulsatile flow, high shear layers lead to greater unsteadiness in the Newtonian case relative to the non-Newtonian case. This, in turn, results in a tendency for the non-Newtonian model to need fewer computational resources even though it has to perform additional calculations for the viscosity. It is also shown that both viscosity models predict comparable wall shear stress distribution. This work suggests that the use of a non-Newtonian viscosity models may be attractive to solve cardiovascular flows since it can provide simulation results that are presumably physically more realistic with at least comparable computational effort for a given level of accuracy.
Skip Nav Destination
Article navigation
October 2014
Research-Article
Numerical Study of Purely Viscous Non-Newtonian Flow in an Abdominal Aortic Aneurysm
Victor L. Marrero,
Victor L. Marrero
Scientific Computation Research Center
and Department of Mechanical,
Aerospace and Nuclear Engineering,
and Department of Mechanical,
Aerospace and Nuclear Engineering,
Rensselaer Polytechnic Institute
,Troy, NY 12180
Search for other works by this author on:
John A. Tichy,
John A. Tichy
1
Scientific Computation Research Center
and Department of Mechanical,
Aerospace and Nuclear Engineering,
and Department of Mechanical,
Aerospace and Nuclear Engineering,
Rensselaer Polytechnic Institute
,Troy, NY 12180
1Corresponding author.
Search for other works by this author on:
Onkar Sahni,
Onkar Sahni
Scientific Computation Research Center
and Department of Mechanical,
Aerospace and Nuclear Engineering,
and Department of Mechanical,
Aerospace and Nuclear Engineering,
Rensselaer Polytechnic Institute
,Troy, NY 12180
Search for other works by this author on:
Kenneth E. Jansen
Kenneth E. Jansen
Department of Aerospace Engineering Sciences,
University of Colorado
,Boulder, CO 80309
Search for other works by this author on:
Victor L. Marrero
Scientific Computation Research Center
and Department of Mechanical,
Aerospace and Nuclear Engineering,
and Department of Mechanical,
Aerospace and Nuclear Engineering,
Rensselaer Polytechnic Institute
,Troy, NY 12180
John A. Tichy
Scientific Computation Research Center
and Department of Mechanical,
Aerospace and Nuclear Engineering,
and Department of Mechanical,
Aerospace and Nuclear Engineering,
Rensselaer Polytechnic Institute
,Troy, NY 12180
Onkar Sahni
Scientific Computation Research Center
and Department of Mechanical,
Aerospace and Nuclear Engineering,
and Department of Mechanical,
Aerospace and Nuclear Engineering,
Rensselaer Polytechnic Institute
,Troy, NY 12180
Kenneth E. Jansen
Department of Aerospace Engineering Sciences,
University of Colorado
,Boulder, CO 80309
1Corresponding author.
Manuscript received October 26, 2012; final manuscript received April 11, 2014; accepted manuscript posted April 24, 2014; published online August 6, 2014. Assoc. Editor: Ender A. Finol.
J Biomech Eng. Oct 2014, 136(10): 101001 (10 pages)
Published Online: August 6, 2014
Article history
Received:
October 26, 2012
Revision Received:
April 11, 2014
Accepted:
April 24, 2014
Citation
Marrero, V. L., Tichy, J. A., Sahni, O., and Jansen, K. E. (August 6, 2014). "Numerical Study of Purely Viscous Non-Newtonian Flow in an Abdominal Aortic Aneurysm." ASME. J Biomech Eng. October 2014; 136(10): 101001. https://doi.org/10.1115/1.4027488
Download citation file:
Get Email Alerts
Related Articles
An Experimental Study of Newtonian and Non-Newtonian Flow Dynamics in a Ventricular Assist Device
J Biomech Eng (May,1987)
Transition to Turbulence Downstream of a Stenosis for Whole Blood and a Newtonian Analog Under Steady Flow Conditions
J Biomech Eng (March,2022)
A Fluid Dynamics Study in a 50 cc Pulsatile Ventricular Assist Device: Influence of Heart Rate Variability
J Biomech Eng (October,2011)
A Modification of Murray's Law for Shear-Thinning Rheology
J Biomech Eng (May,2015)
Related Proceedings Papers
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Investigation of the Dynamic Characteristics of Cardio-Respiratory Response OT Treadmill Running Exercise for Interval Training
International Conference on Measurement and Control Engineering 2nd (ICMCE 2011)
Two Advanced Methods
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine