Technical Papers
Bone/Orthopedic
Effect of Microcomputed Tomography Voxel Size on the Finite Element Model Accuracy for Human Cancellous Bone
J Biomech Eng. February 2005, 127(1): 1–8.
doi: https://doi.org/10.1115/1.1835346
Topics:
Bone
,
Resolution (Optics)
,
Finite element model
,
Stress
,
Boundary-value problems
,
Simulation
Finite Element Prediction of Proximal Femoral Fracture Patterns Under Different Loads
J Biomech Eng. February 2005, 127(1): 9–14.
doi: https://doi.org/10.1115/1.1835347
Topics:
Anisotropy
,
Bone
,
Finite element analysis
,
Fracture (Materials)
,
Fracture (Process)
,
Stress
,
Density
,
Tensors
,
Bone fractures
,
Textiles
Material Properties of the Human Lumbar Facet Joint Capsule
J Biomech Eng. February 2005, 127(1): 15–24.
doi: https://doi.org/10.1115/1.1835348
Topics:
Dynamic testing (Materials)
,
Fibers
,
Relaxation (Physics)
,
Stress
,
Displacement
,
Materials properties
Cell
Mechanical Properties of Laser Cut Poly(L-Lactide) Micro-Specimens: Implications for Stent Design, Manufacture, and Sterilization
J Biomech Eng. February 2005, 127(1): 25–31.
doi: https://doi.org/10.1115/1.1835349
Topics:
Creep
,
Design
,
Lasers
,
Manufacturing
,
Mechanical properties
,
Polymers
,
Stents
,
Sterilization
,
Thermoelectric coolers
,
Thermomechanics
Fluids/Heat/Transport
Study of SARS Transmission Via Liquid Droplets in Air
J Biomech Eng. February 2005, 127(1): 32–38.
doi: https://doi.org/10.1115/1.1835350
Topics:
Drops
,
Evaporation
The Flow Field Downstream of an Oscillating Collapsed Tube
J Biomech Eng. February 2005, 127(1): 39–45.
doi: https://doi.org/10.1115/1.1835351
Topics:
Cycles
,
Flow (Dynamics)
,
Oscillations
,
Collapse
,
Pipes
,
Lasers
A Mathematical Model of Alveolar Gas Exchange in Partial Liquid Ventilation
J Biomech Eng. February 2005, 127(1): 46–59.
doi: https://doi.org/10.1115/1.1835352
Topics:
Biological tissues
,
Blood
,
Carbon dioxide
,
Diffusion (Physics)
,
Pressure
,
Ventilation
,
Convection
,
Lung
,
Tides
,
Mass transfer
Mathematical Model for Pressure Losses in the Hemodialysis Graft Vascular Circuit
Steven A. Jones, Associate Professor,, Song Jin, Postdoctoral Fellow,, Ameya Kantak, Graduate Student,, David A. Bell, Chief Technical Officer,, William D. Paulson, Professor of Medicine,
J Biomech Eng. February 2005, 127(1): 60–66.
doi: https://doi.org/10.1115/1.1835353
Topics:
Circuits
,
Flow (Dynamics)
,
Hemodialysis
,
Inflow
,
Outflow
,
Pressure
,
Turbulence
,
Viscosity
,
Hemodynamics
,
Thrombosis
Bioheat and Mass Transfer as Viewed Through a Microscope
J Biomech Eng. February 2005, 127(1): 67–84.
doi: https://doi.org/10.1115/1.1835354
Topics:
Freezing
,
Ice
,
Mass transfer
,
Microscopes
,
Temperature
,
Cooling
,
Stress
,
Membranes
,
Water
Thermal Damage Prediction for Collagenous Tissues Part I: A Clinically Relevant Numerical Simulation Incorporating Heating Rate Dependent Denaturation
J Biomech Eng. February 2005, 127(1): 85–97.
doi: https://doi.org/10.1115/1.1835355
Topics:
Biological tissues
,
Damage
,
Heating
,
Lasers
,
Temperature
,
Simulation
,
Heat
Joint/Whole Body
Determining Dual Euler Angles of the Ankle Complex in vivo Using “Flock of Birds” Electromagnetic Tracking Device
J Biomech Eng. February 2005, 127(1): 98–107.
doi: https://doi.org/10.1115/1.1846072
Topics:
Kinematics
,
Rotation
,
Compression
,
Bone
Sudden Loading During a Dynamic Lifting Task: A Simulation Study
J Biomech Eng. February 2005, 127(1): 108–113.
doi: https://doi.org/10.1115/1.1835357
Topics:
Muscle
,
Simulation
,
Stress
,
Compression
,
Dynamics (Mechanics)
,
Bone
,
Risk
Virtual Slope Control of a Forward Dynamic Bipedal Walker
J Biomech Eng. February 2005, 127(1): 114–122.
doi: https://doi.org/10.1115/1.1835358
Topics:
Control equipment
,
Dynamics (Mechanics)
,
Eigenvalues
,
Pendulums
,
Simulation
,
Stability
,
Steady state
,
Torque
,
Trajectories (Physics)
,
Kinematics
Simulating Dynamic Activities Using a Five-Axis Knee Simulator
J Biomech Eng. February 2005, 127(1): 123–133.
doi: https://doi.org/10.1115/1.1846070
Soft Tissue
The Relationship of Normal and Abnormal Microstructural Proliferation to the Mitral Valve Closure Sound
J Biomech Eng. February 2005, 127(1): 134–147.
doi: https://doi.org/10.1115/1.1835359
Topics:
Acoustics
,
Biological tissues
,
Fibers
,
Stiffness
,
Stress
,
Valves
,
Signals
,
Flow (Dynamics)
,
Diseases
,
Sound pressure
Method and Apparatus for Soft Tissue Material Parameter Estimation Using Tissue Tagged Magnetic Resonance Imaging
J Biomech Eng. February 2005, 127(1): 148–157.
doi: https://doi.org/10.1115/1.1835360
A Comparison Between Mechano-Electrochemical and Biphasic Swelling Theories for Soft Hydrated Tissues
J Biomech Eng. February 2005, 127(1): 158–165.
doi: https://doi.org/10.1115/1.1835361
Topics:
Biological tissues
,
Cartilage
,
Compression
,
Deformation
,
Finite element analysis
,
Permeability
,
Pressure
,
Materials properties
,
Simulation
,
Stress
Changes in the Mechanical Environment of Stenotic Arteries During Interaction With Stents: Computational Assessment of Parametric Stent Designs
J Biomech Eng. February 2005, 127(1): 166–180.
doi: https://doi.org/10.1115/1.1835362
Topics:
Stents
,
Struts (Engineering)
,
Stress
,
Pressure
Influence of Decorin and Biglycan on Mechanical Properties of Multiple Tendons in Knockout Mice
J Biomech Eng. February 2005, 127(1): 181–185.
doi: https://doi.org/10.1115/1.1835363
Topics:
Tendons
,
Stress
,
Relaxation (Physics)
,
Mechanical properties
,
Biological tissues
Technical Briefs
Influence of Cervical Disc Degeneration after Posterior Surgical Techniques in Combined Flexion-Extension—A Nonlinear Analytical Study
J Biomech Eng. February 2005, 127(1): 186–192.
doi: https://doi.org/10.1115/1.1835364
Topics:
Biomechanics
,
Bone
,
Cervical spine
,
Disks
,
Surgery
,
Rotation
,
Finite element analysis
,
Stress
,
Annulus
Simultaneous Measurement of Three-Dimensional Joint Kinematics and Ligament Strains With Optical Methods
J Biomech Eng. February 2005, 127(1): 193–197.
doi: https://doi.org/10.1115/1.1835365
Topics:
Kinematics
,
Strain measurement
Trabecular Bone Contributes to Strength of the Proximal Femur Under Mediolateral Impact in the Avian
J Biomech Eng. February 2005, 127(1): 198–203.
doi: https://doi.org/10.1115/1.1835366
Topics:
Biological tissues
,
Bone
,
Fracture (Materials)
,
Fracture (Process)
,
Weight (Mass)
,
Osteoporosis
,
Stress
,
Joules
Single-Step Stereolithography of Complex Anatomical Models for Optical Flow Measurements
J Biomech Eng. February 2005, 127(1): 204–207.
doi: https://doi.org/10.1115/1.1835367
Errata
Erratum: “Effect of Fluid Boundary Conditions on Joint Contact Mechanics and Applications to the Modelling of Osteoarthritic Joints,” J. Biomech. Eng., 126(2), pp. 220–225
J Biomech Eng. February 2005, 127(1): 208–209.
doi: https://doi.org/10.1115/1.1835985
Email alerts
RSS Feeds
Effect of Blade Thickness on Hemodynamics and Hemolysis: A Case Study of Pediatric Centrifugal Blood Pumps
J Biomech Eng (February 2025)
Estimation of Joint Kinetics During Manual Material Handling Using Inertial Motion Capture: A Follow-Up Study
J Biomech Eng (February 2025)
Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues
J Biomech Eng (February 2025)
Eyelid Motion Tracking During Blinking Using High-Speed Imaging and Digital Image Correlation
J Biomech Eng (January 2025)