Advanced design of human artificial joints requires an in-depth understanding of the dynamic interaction between the very stiff bone replacement material and the softer viscoelastic cartilage replacement material. It must take into account both the large displacement gross motions as well as the small displacement elastic responses. A co-simulation methodology has been developed in BRG LifeMOD, connecting Adams∕Solver, a large displacement multi-body dynamics code, to Marc, a nonlinear finite element code. This efficient co-simulation approach allows for each code to handle that portion of the system for which it is most capable, while adding the potential to work across multiple CPUs and operating systems as desired. The method was applied using LifeMOD∕KneeSIM to simulate an artificial knee joint, containing cobalt chromium steel and ultra-high molecular weight polyethylene contact elements, undergoing a normal walking gait to predict kinematics, forces and the resulting wear patterns.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Human Joint Simulation Using LifeMOD Co-Simulation
Eric Fahlgren,
Eric Fahlgren
MSC.Software & Biomechanics Research Group
Search for other works by this author on:
Mark Carlson,
Mark Carlson
MSC.Software & Biomechanics Research Group
Search for other works by this author on:
Andrew S. Elliott
Andrew S. Elliott
MSC.Software & Biomechanics Research Group
Search for other works by this author on:
Eric Fahlgren
MSC.Software & Biomechanics Research Group
Mark Carlson
MSC.Software & Biomechanics Research Group
Andrew S. Elliott
MSC.Software & Biomechanics Research Group
J. Med. Devices. Jun 2008, 2(2): 027549 (1 pages)
Published Online: June 25, 2008
Article history
Published:
June 25, 2008
Citation
Fahlgren, E., Carlson, M., and Elliott, A. S. (June 25, 2008). "Human Joint Simulation Using LifeMOD Co-Simulation." ASME. J. Med. Devices. June 2008; 2(2): 027549. https://doi.org/10.1115/1.2932506
Download citation file:
698
Views
Get Email Alerts
Cited By
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Novel re-entrant porous composite structure: a potential for orthopaedic applications
J. Med. Devices (June,2008)
Design of an Endoreactor for the Cultivation of a Joint-Like-Structure
J. Med. Devices (June,2009)
PMMA Implants Increase Femoral Strength
J. Med. Devices (June,2008)
Real-Time, In Vivo Measurement of Contact Pressures at a Knee Arthroplasty
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Processing/Structure/Properties Relationships in Polymer Blends for the Development of Functional Polymer Foams
Advances in Multidisciplinary Engineering
Effectiveness of Minimum Quantity Lubrication (MQL) for Different Work Materials When Turning by Uncoated Carbide (SNMM and SNMG) Inserts
Proceedings of the 2010 International Conference on Mechanical, Industrial, and Manufacturing Technologies (MIMT 2010)
Development of New Process and Product Monitoring Technologies for the Manufacturing of High Value Alloy Steels for Use in Critical Applications
Bearing and Transmission Steels Technology