This paper presents field test of a hybrid solar liquid desiccant cooling system conducted at a test house at the University of Florida’s Energy Research and Education Park. These tests consisted of operating the air conditioning system at the test house in two configurations: the conventional vapor compression system and the hybrid desiccant system. Experiments were conducted to study the influence of the air mass flow rate, temperature of the inlet air, temperature of the desiccant, and desiccant mass flow rate on the performance of both system configurations. Based on the field test results, it was found that the hybrid desiccant system improves the air conditioning performance in the field test house by decreasing the outlet humidity and temperature of the air.
Skip Nav Destination
Article navigation
February 2003
Technical Briefs
A Study of the Performance of a Hybrid Liquid Desiccant Cooling System Using Lithium Chloride
Pedro Mago,
Pedro Mago
Department of Mechanical Engineering, Universidad de Oriente, Puerto La Cruz, Anzoategui, Venezuela
**
Search for other works by this author on:
D. Yogi Goswami
D. Yogi Goswami
Solar Energy and Energy Conversion Laboratory, Department of Mechanical Engineering, University of Florida, Gainesville, FL 32611
Search for other works by this author on:
Pedro Mago
**
Department of Mechanical Engineering, Universidad de Oriente, Puerto La Cruz, Anzoategui, Venezuela
D. Yogi Goswami
Solar Energy and Energy Conversion Laboratory, Department of Mechanical Engineering, University of Florida, Gainesville, FL 32611
Contributed by the Solar Energy Division of THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS for publication in the ASME JOURNAL OF SOLAR ENERGY ENGINEERING. Manuscript received by the ASME Solar Energy Division, February 2001; final revision, August 2002. Associate Editor: V. Mei.
J. Sol. Energy Eng. Feb 2003, 125(1): 129-131 (3 pages)
Published Online: January 27, 2003
Article history
Received:
February 1, 2001
Revised:
August 1, 2002
Online:
January 27, 2003
Citation
Mago, P., and Goswami , D. Y. (January 27, 2003). "A Study of the Performance of a Hybrid Liquid Desiccant Cooling System Using Lithium Chloride ." ASME. J. Sol. Energy Eng. February 2003; 125(1): 129–131. https://doi.org/10.1115/1.1530199
Download citation file:
Get Email Alerts
Experimental Investigation of Natural Circulating Solar Energy System Including a Parabolic Trough Solar Collector
J. Sol. Energy Eng (April 2025)
Theoretical and Experimental Study of Heat Transfer in a Two-Channel Flat Plate Solar Air Collector
J. Sol. Energy Eng (April 2025)
Related Articles
Energy Saving Potential of a Combined Solar and Natural Gas-Assisted Vapor Absorption Building Cooling System
J. Sol. Energy Eng (February,2019)
Experimental Study on a Hybrid Desiccant Dehumidification and Air Conditioning System
J. Sol. Energy Eng (February,2006)
A Liquid Desiccant System for Solar Cooling and Dehumidification
J. Sol. Energy Eng (August,2004)
Simulation of an Air-Cooled Solar-Assisted Absorption Air Conditioning System
J. Sol. Energy Eng (August,2002)
Related Proceedings Papers
Related Chapters
Two-Stage Liquid Desiccant Dehumidification∕Regeneration
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Characteristics, Components, and Performance of A/C System Exchangers
Heat Exchanger Engineering Techniques
Numerical Simulation and Analysis about Harmonic Performance Used for Heat Transfer and Air-Conditioning Cooling Load of Energy-Saving Porous Brick and Hollow Brick Wall
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)